Sheet E-001
Engineering Tools
Free calculators and viewers our engineers use on real projects. Each one runs in your browser and sends nothing to us. Bookmark the ones you use.
Bus ACables and raceways
MV Cable Ampacity CalculatorMedium-voltage cables to 35 kV, buried or in air, with a conduit size and type for each duct, including paper-insulated lead-covered and armoured cables. Steady-state and emergency ratings in amperes and MVA, sequence impedances and charging current, several cases per project, and a heat map of the duct bank.IEC 60287, Neher-McGrath, CarsonLV Cable Ampacity CalculatorCables from 600 V to 2 kV in duct banks, direct buried, in conduit in air or in free air, from the NEC tables or by Neher-McGrath.NEC 2023, Neher-McGrathCable Pulling CalculatorPulling tension and sidewall bearing pressure along a conduit route, in both directions, for cable to 35 kV.IEEE 1185, Southwire guideConduit Fill CalculatorFill for building wire, medium-voltage cable to 35 kV, Ethernet and fiber, with jam ratio and clearance checks.NEC Chapter 9Cable Testing LabHow power cable field tests work: insulation resistance, PI and DAR, sheath, VLF, tan delta, partial discharge and TDR. Each test has a connection diagram, a live result to explore with sliders, and what it shows and misses.IEEE 400 series (concepts), IEC 60287 capacitance
Bus BShort circuit and arc flash
Fault Current CalculatorSingle- and three-phase bolted fault current from the utility source to the end of the cable.Ohmic methodShort Circuit and Arc FlashDraw a low-voltage one-line to 480 V ac or 1500 V dc, or build it from an ETAP project, then get fault currents, device coordination and arc flash labels.IEEE 1584, NFPA 70E, IEEE C57.109Sequence Fault VisualizerHow a fault's currents split into positive, negative and zero sequence across a transformer, including ground faults on ungrounded systems through cable capacitance and on 12.47 kV lines: a 3-wire vs 4-wire view that shows the 4-wire, hybrid and 3-wire constructions side by side for the same feeder, with a one-line of the station and feeder and a side view from the switchgear of each construction showing the ground-fault current coming back on the neutral and through the earth, presets for bolted and high-resistance faults at different distances, the grounds as built, underground sections, a ground relay with its time-to-trip against a typical branch-line fuse (which clears first), IEEE's coefficient of grounding in percent and kilovolts with its definition beside it, the arrester voltage on the worst fault to the local ground, voltage rise and how long it lasts, an arrester rating from the voltage across it and whether the fault clears, the equipment ratings each construction's fault duty decides (cable insulation level and short-circuit times, separable connectors, fuse cutouts, capacitor units, line insulators), the code requirements that differ between the three (grounding intervals, 3.5 ohm to ground, return paths, clearances under GO 95, GO 128 and the NESC), a choice of overhead trunk, lateral and neutral conductors and underground cables, a printable calculation sheet that shows each step's equation and value for 4-wire, hybrid and 3-wire, and a Downed conductor tab that shows where a downed wire's current goes on each construction (through its contact, the pole's ground rod, the neutral and the earth back to the station grid) with the ground's potential as a gradient in a cross-section, from above and as a 3D bowl, the current drawn flowing, step and touch voltages, how it all changes with the distance from the ground rod, each part's resistance to remote earth, the soil around the wire drawn as shells that hold half the ohms each time they double, the ohms near the electrodes against the earth's 0.095 ohm per mile back along the line, and how much of the current goes into the neutral and how much into the soil, and a Conversion cost tab that prices converting a 4.8 kV 3-wire delta overhead system to 12.47 kV as 4-wire, hybrid or 3-wire, item by item (the neutral, taller poles, raised crossarms, grounds, transformers, arresters, underground cable, the cutover, standards and upkeep), with sliders for the feeders' lengths, a crew at the state's prevailing wage and every quantity and price editable.Symmetrical components, IEEE C62.92.1, C62.92.4, C62.22, C37.112, IEEE 80, IEEE 386, IEEE 18, ICEA P-32-382, P-45-482, GO 95, GO 128, NESC
Bus CBuilding circuits and equipment
Circuit CalculatorBranch circuits and feeders of 1000 V and less: protection, conductors, grounding, raceways and voltage drop.NEC 2023Transformer CalculatorProtection, conductors, grounding and raceways for transformers of 1000 V and less.NEC 2023Motor CalculatorBranch circuits for motors of 1000 V and less: protection, conductors, grounding, raceway and control.NEC 2023Panel Schedule CalculatorPanelboard and switchboard schedules, branch-circuit sizing and load calculations.NEC 2023
Bus DOverhead distribution
Bus EPower system models
SKM ViewerOpen an SKM PowerTools project in your browser: the one-line diagram, load flow, short circuit and cable ampacity, with each cable's construction, its duct bank and conduit fill, and a printable report. Nothing is uploaded.SKM PowerTools projects, IEC 60287ETAP ViewerOpen an ETAP project in your browser: the one-line, load flow, short circuit and arc flash, with clearing times from SEL relays. Nothing is uploaded.ETAP projects, IEEE 1584PSLF ViewerOpen GE PSLF EPC, DYD and DRW files: one-line, power flow, short circuit, dynamics and WECC data checks. Nothing is uploaded.GE PSLF, WECC checks
Bus FDrawings
Bus GGrounding
Grounding StudioSubstation and equipment grounding to IEEE 80: Wenner soil readings fitted to a layered soil model, ground grids drawn or imported from DXF, DWG and DGN, a recommended split factor from the circuits at the site, a check of every fault location, and touch, step and GPR maps from a numerical model in uniform or two-layer soil, with example soils, grids and systems to start from. For teaching and early design.IEEE 80, IEEE 81Vault GroundingShield and sheath grounding in combination vaults and at pad-mounted equipment: how two rods in one vault share potential, separate or bonded ground buses for a 34.5 kV system with 4.8 kV ungrounded delta or 12.47 kV multigrounded or single-grounded cables, transferred voltage along shields, sheaths and neutrals to the next vaults, a 4.8 kV ground fault left on for hours, touch and step voltages, and grounding conductor sizing. For teaching and early design.IEEE 80, IEEE 575, NESC
Bus HEngineering economics
Loan Amortization CalculatorLoan payments and the full payoff schedule, with extra payments, interest-only and balloon terms, and a side-by-side refinance comparison.Time value of moneyInvestment Growth CalculatorSavings growth with regular contributions, or the contribution, return or time needed to reach a goal, with inflation and interest factors.Time value of moneyProject Economics CalculatorNet present value, IRR, payback and levelized cost of energy for capital projects such as solar, battery storage and efficiency upgrades.NPV, IRR, LCOE
Bus IProtection and relaying
Protection LabHow protective relays measure, decide and trip: 31 ANSI device functions, a feeder coordination lab and a transformer differential and inrush lab, with the reason behind every trip and every restraint.IEEE C37.2, C37.112, C37.91Transformer Fusing LabPrimary fusing for pad-mounted and underground transformers: Bay-O-Net links (dual sensing, current sensing, dual element, Kearney and high ampere) with 8.3, 15.5 and 23 kV backup current-limiting fuses, full-range NX and ELX fuses, external S&C SM-4 and SM-5 power fuses, and utility fusing configurations, coordinated from the manufacturers' curves, with transformer protection against the IEEE C57.109 through-fault curves (and where the fuse crosses them), loading requirements and secondary arc flash, and the status and reason behind every result.IEEE C57.12.00, C57.109, IEEE 1584Relay SettingsOpen SEL relay settings (SET files, terminal captures or a QuickSet .rdb) to view, edit, check and compare them, with setpoint graphics, TCCs, SELOGIC diagrams and typical settings from equipment ratings, and view Beckwith setpoint reports. Nothing is uploaded.SEL settings files, IEEE C37.112, IEEE C57.109
Bus JDrones and mapping
Aerial3D WaypointsPlan waypoint missions for photogrammetry and 3D models with the DJI Mini 5 Pro: nadir grids, oblique cross-grids, orbits, facade scans and free waypoint paths, exported as DJI Fly KMZ files.DJI WPML (KMZ)Aerial3D ModelTurn drone photos and ground-level 360 photos and video (including Insta360 .insp and .insv originals) from one or more folders into an orthophoto, elevation models, a point cloud and a textured 3D mesh, with or without GPS, and add new photos to a finished model. The page is the front end; the processing runs on your own PC with the free Aerial3D Engine.COLMAP and OpenMVS; GeoTIFF, LAZ, GLB and OBJView360Scroll through a folder of photos, 360 photos and 360 videos, including unstitched Insta360 .insp and .insv originals, stitched and leveled in your browser from the camera's own lens and tilt data. Mark up photos with clouds, callouts, text, arrows and crop, export a 360 JPG, and see where each photo was taken on a map linked to Google Maps and Google Earth. Nothing is uploaded.Insta360 X5; equirectangular JPG with GPano XMP